Power Generation :: SSS Clutch for CAES
SSS Clutches are used in the Huntorf Pumped Air Storage Plant for transmitting
power from the turbines to the motor/generator during generation mode
and from the motor/generator in the compression mode.
 |
| The rotating machinery at Huntorf
CAES power station. |
• The turbine side SSS Clutch transmits 300MW at 3000rpm.
• The compressor side SSS Clutch transmits 80MW at 3000rpm.
The clutches have been operating since 1978 without special maintenance
or any replacement parts.
|
| Size 340T SSS Clutch transmits 300MW at Huntorf
CAES power station. |
|
| Simplified machinery arrangement of a CAES plant
with SSS Clutches |
|